• LZW-72.5 Outdoor Current Transformer
LZW-72.5 Outdoor Current Transformer
discuss personally
Model
LZW-72.5
Basic info
Brand Wone Store
Model NO. LZW-72.5 Outdoor Current Transformer
Rated voltage 66kV
Rated frequency 50/60Hz
Rated current ratio 500/5
Series LZW
Product Detail

Product Overview

LZW-72.5 current transformer, epoxy resin casting insulation and outdoor installation, is widely used for measuring current, electric energy and protective relaying in the power system with the rated frequency 50Hz or 60 Hz and rated voltage 66kV or 69kV.

Key Features

  • High-Voltage Grade Outdoor-Specific Design:The LZW-72.5 features a 72.5kV rated voltage design with insulation levels reaching 125kV (lightning impulse) / 70kV (power frequency withstand voltage). It strictly complies with GB/T 4703.2 and IEC 60044-2 standards, optimized for high-voltage outdoor scenarios such as 110kV and below outdoor substations and overhead lines. This ensures safe and stable operation in long-term high-voltage environments, effectively reducing the risk of insulation breakdown.

  •  Extreme Climate Protection Structure:The product incorporates a triple protection system: it uses silicone rubber composite insulation materials and aluminum alloy flanges, achieving 10,000 hours of UV aging resistance; reaches IP68+ protection, enabling long-term operation at 2 meters underwater, with special designs to withstand 30mm/h snow accumulation and ice loads up to 20mm thickness; passes 3,000 hours of salt spray testing, with a creepage distance of 31mm/kV, fully meeting the requirements of harsh outdoor environments such as plateaus, extreme cold, and coastal areas.

  • Dual-Winding High-Precision Measurement System:The LZW-72.5 integrates a 0.2S-class metering winding and a 5P30-class protection winding. The metering winding maintains a ratio error ≤±0.2% within 1%~120% rated current, meeting high-precision energy metering needs; the protection winding has a composite error ≤5% at 30 times rated current with 8ms fast response, effectively ensuring the speed of relay protection devices. It includes 3 sets of ratio taps (e.g., 600/5A, 800/5A, 1000/5A), which can be flexibly adjusted via an outdoor-specific sealed switch without disassembly to adapt to different load current scenarios.

  • Intelligent Condition Monitoring and Communication Technology:The product is equipped with multi-parameter sensors for temperature (-40℃~+120℃), humidity, and insulation dielectric loss, collecting real-time operational data. It supports IEC 61850-9-2 digital protocol and DL/T 645 standard, while retaining a 4~20mA analog output interface, enabling seamless integration into smart substation systems or compatibility with old monitoring equipment. In-depth analysis of historical data through cloud platforms predicts insulation aging trends in advance, providing data support for operation and maintenance decisions and significantly reducing outdoor inspection frequency and costs.

Main technical parameter

  • Rated voltage : 66kV or 69kV

  • Highest voltage for equipment : 72.5 kV

  • Rated insulation level : 72.5/140/325kV

  • Rated secondary current :5Aor1A

  • Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers or ANSI IEEE STD C57.13-2008

Other technical parameter pls see as follow:

Double ratios

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline drawing

 

 

 

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!